Calibration Lamp Sets

Calibration Lamp SetsCalibrated Lamps are used to assure photometric accuracy of spheres that are in field use. The calibrated lamps are calibrated in a Master 12” sphere using reference lamps. The light output of each lamp is certified to be accurate within 3% of absolute.

Each calibrated lamp set is furnished in a protective wooden case with foam inserts and space for storing the calibration certificate.  Each lamp is marked with a unique serial number to allow traceability.

SUBMINIATURE ADAPTOR PLATE CALIBRATED LAMP SETS
 
Designed for use with WPL Model 526B MOD2 and Model 504D MOD1 Photometric Spheres

We offer subminiature Adaptor Plate calibrated lamps in serialized sets of three (for drift protection). The calibrated lamps are carefully aged and selected before being permanently affixed to an adaptor board which features gold plated electrical contacts. The lamp filaments are selected to have have a low voltage/high current relationship to provide ruggedness and long-term stability.

PART NO.

DESCRIPTION

530A-0100

100 Spherical millicandela Calibrated Lamp Set

530A-0250

250 Spherical millicandela Calibrated lamp Set

530A-1000

1000 Spherical millicandela Calibrated Lamp Set

UN-BASED MINIATURE CALIBRATED LAMP SET

We offer subminiature and miniature un-based calibrated lamps in serialized sets of three. The calibrated lamps are carefully aged and selected before calibration. The subminiature lamps come in a bi-pin configuration and the miniature lamps all use industry standard S8 bases. The use of these calibrated lamps in the 504D and 526B series products requires the correct WPL Lamp Adaptor.

Part No.

Description

Base Type

Recommended WPL Lamp Base Adaptor

530A-155-100
(Bi-Pin)

100 millicandela

Bi-Pin

530A-111

526A-216

3.0 candela

S8

530A-118

526A-215

10.0 candela

S8

530A-118

526B-219

50.0 candela

S8

530A-118

526B-220 MIXED SET (3 Calibrated Lamps)

The 526B-220 Mixed calibration lamp set is specifically designed for calibration of the Model 526B MOD 2 Lamp Analyzer. This set comprises three different lamps with multiple calibrations on each lamp. The information on the calibration certificate can be directly entered into the 526B MOD 2 for use with its automated calibration procedure.

Lamp

MSCD (mean spherical candela)

Base Type

WPL Adaptor

#1

.010, 1.000

Adaptor Plate

N/A

#2

.025, 0.100, 0.250

Adaptor Plate

N/A

#3

1000, 100.0

S8

530A-118

Copyright © 2000-2009 Dupree, Inc. All Rights Reserved